Novus myPCLab EN Instrukcja Użytkownika Strona 4

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 9
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 3
myPCLab
NOVUS AUTOMATION 4/9
0-50 mV WIRING
Connections of channel 1 are on terminals 6 and 7. For channel 2 on terminals 2 and 3.
Observe indicated polarity.
0-10 V WIRING
Linear voltage signals from 0 to 10 V can only be connected to channel 1, terminals 5 and 6.
Observe indicated polarity.
DRY CONTACT DIGITAL INPUT WIRING
Digital signals are connected to channel 3, terminals 1 and 2.
The contact connected to digital input must not have any electrical voltage.
VOLTAGE DIGITAL INPUT WIRING
Digital signals are connected to channel 3, terminals 1 and 2. Observe indicated polarity.
Voltage levels applied to this channel must be within the specified limits. See “Specifications”.